Kit Summary
The Human Anti-Dengue Virus IgG ELISA Kit is a 3.5 hour solid phase ELISA designed to measure Dengue Virus IgG antibodies in human serum and EDTA plasma.
Key Benefits
- High specificity with minimal cross-reactivity with Zika Virus IgG antibodies
- High sensitivity
- Detection of Dengue Virus IgG antibodies later in the infection when IgM antibodies may be undetectable
Principle of the Assay
This is an antigen-down enzyme immunoassay where recombinant Dengue Virus strains 1, 2, 3, & 4 NS1 antigens are pre-coated onto a 96-well microplate and used to bind antibodies found in the sample. When the sample is added (such as human serum or EDTA plasma), antibodies found in the sample that recognize Dengue Virus NS1 antigens bind the antigen coated plate and are retained in the well. After washing away unbound substances, an enzyme linked polyclonal antibody specific for human IgG is added to the wells. Following a wash to remove any unbound enzyme linked antibody, a substrate is added to the wells and color develops in proportion to the amount of IgG antibodies in the sample bound to the Dengue Virus NS1 antigens. The color development is stopped, and the intensity of the color is measured.
The potential for false positives due to Dengue Virus NS1 antigen cross-reactive antibodies to related flaviviruses, such as Zika Virus, is minimized by treatment of the samples. Samples are treated with a propriety treatment reagent prior to being added to the Dengue Virus NS1 antigen coated plate. Sample specific background is determined by adding identically treated samples to an uncoated background plate and measuring the amount of IgG antibodies non-specifically bound to the well. To interpret results, net sample OD readings are calculated by subtracting each sample background plate reading from the Dengue Virus NS1 antigen plate reading.
Precision
Intra-Assay Precision (Precision within an assay)
Three Anti-Dengue Virus IgG positive samples with low, middle, and high net O.D. were tested twenty-four times on one plate to assess intra-assay precision.
Inter-assay Precision (Precision between assays)
Three Anti-Dengue Virus IgG positive samples with low, middle, and high net O.D. were tested in twenty separate assays to assess inter-assay precision. Assays were performed by at least three technicians.
| Intra-Assay Precision | Inter-Assay Precision |
Sample | 1 | 2 | 3 | 1 | 2 | 3 |
n | 24 | 24 | 24 | 20 | 20 | 20 |
Net O.D. | 0.838 | 1.776 | 2.811 | 0.709 | 1.556 | 2.756 |
Standard deviation | 0.019 | 0.033 | 0.039 | 0.079 | 0.151 | 0.276 |
CV (%) | 2.3 | 1.9 | 1.4 | 11.1 | 9.7 | 10 |
Specificity
This assay recognizes Dengue Virus specific human IgG antibodies with minimal cross-reactivity of human Zika IgG antibodies.
Background: Dengue virus
Dengue fever is a mosquito-borne tropical disease caused by the Dengue Virus (DENV), a member of the flavivirus genus. Symptoms of Dengue fever include a high fever, headache, vomiting, muscle and joint pains and a characteristic skin rash. In a small proportion of cases, the disease develops into the life-threatening Dengue hemorrhagic fever, which results in bleeding, low levels of blood platelets and blood plasma leakage, or into Dengue shock syndrome, where dangerously low blood pressure occurs (1). The incidence of Dengue Virus infections has grown dramatically around the world in recent decades. The actual numbers of Dengue cases are underreported, and many cases are misclassified. One recent estimate indicates 390 million Dengue infections per year of which 96 million manifest a level of disease severity (2). Serological diagnosis of Dengue infection is complicated by cross-reactivity among other flaviviruses, such as Zika Virus (ZIKV) (3). Because DENV, ZIKV, and other flavivirus co-circulate in endemic regions and share high sequence similarity, there is a high possibility of IgM and IgG cross-reactivity in immunoassays (4). There is a need for a simple serological test that displays high Dengue specificity with minimal cross-reactivity with other flaviviruses.
References:
- Kularatne, S.A. (2015) BMJ, 351:h4661.
- Bhatt, S. et al. (2013) Nature, 496:504.
- Musso, D. et al. (2016) Clin. Microbiol. Rev. 29:487.
- Cabral-Castro, M.J. et al. (2016) J. Clin. Virol. 82:108.
Product Specifications for Human Anti-Dengue Virus IgG ELISA Kit
Species |
Human
|
Preparation & Storage
Storage |
Store the unopened product at 2 - 8 °C. Do not use past expiration date.
|
Customer Reviews for Human Anti-Dengue Virus IgG ELISA Kit
Have you used Human Anti-Dengue Virus IgG ELISA Kit?
Submit a review and receive an Amazon gift card!
$25/€18/£15/$25CAN/¥2500 Yen for a review with an image
$10/€7/£6/$10CAN/¥1110 Yen for a review without an image
Submit a review
FAQs for Human Anti-Dengue Virus IgG ELISA Kit
Product Documents for Human Anti-Dengue Virus IgG ELISA Kit