Skip to main content

IL-27R alpha/WSX-1/TCCR Antibody (34N4G11) [Alexa Fluor® 350]

Novus Biologicals, part of Bio-Techne | Catalog # NBP2-19015AF350

Novus Biologicals, part of Bio-Techne
Catalog #
Availability
Size / Price
Qty
Loading...
NBP2-19015AF350

Key Product Details

Species Reactivity

Human

Applications

CyTOF-ready, Flow (Cell Surface), Flow Cytometry, Immunohistochemistry, Immunohistochemistry-Paraffin

Label

Alexa Fluor 350 (Excitation = 346 nm, Emission = 442 nm)

Antibody Source

Monoclonal Mouse IgG2b Kappa Clone # 34N4G11

Concentration

Please see the vial label for concentration. If unlisted please contact technical services.

Product Specifications

Immunogen

A portion of amino acids 200-250 of human IL-27R (WSX-1) was used as the immunogen for this antibody.

Localization

Membrane (with Extracellular and Cytoplasmic domains)

Specificity

IL-27R (WSX-1) is 65-70 kDa protein and is highly expressed in lymphoid tissues such as spleen, lymph nodes and peripheral blood leukocytes including CD4+ and CD8+ T cells, monocytes, DCs and NK cells

Clonality

Monoclonal

Host

Mouse

Isotype

IgG2b Kappa

Scientific Data Images for IL-27R alpha/WSX-1/TCCR Antibody (34N4G11) [Alexa Fluor® 350]

IL-27R alpha/WSX-1/TCCR Antibody (34N4G11) [Alexa Fluor® 350]

IL-27R alpha/WSX-1/TCCR Antibody (34N4G11) [Alexa Fluor® 350] [NBP2-19015AF350] -

IL-27R alpha/WSX-1/TCCR Antibody (34N4G11) [Alexa Fluor® 350] [NBP2-19015AF350] - Vial of Alexa Fluor 350 conjugated antibody. Alexa Fluor 350 is optimally excited at 346 nm by the UV laser (350 or 355 nm) and has an emission maximum of 442 nm.

Applications for IL-27R alpha/WSX-1/TCCR Antibody (34N4G11) [Alexa Fluor® 350]

Application
Recommended Usage

CyTOF-ready

Optimal dilutions of this antibody should be experimentally determined.

Flow (Cell Surface)

Optimal dilutions of this antibody should be experimentally determined.

Flow Cytometry

Optimal dilutions of this antibody should be experimentally determined.

Immunohistochemistry

Optimal dilutions of this antibody should be experimentally determined.

Immunohistochemistry-Paraffin

Optimal dilutions of this antibody should be experimentally determined.
Application Notes
Optimal dilution of this antibody should be experimentally determined.

Formulation, Preparation, and Storage

Purification

Protein G purified

Formulation

50mM Sodium Borate

Preservative

0.05% Sodium Azide

Concentration

Please see the vial label for concentration. If unlisted please contact technical services.

Shipping

The product is shipped with polar packs. Upon receipt, store it immediately at the temperature recommended below.

Stability & Storage

Store at 4C in the dark.

Background: IL-27 R alpha/WSX-1/TCCR

Upon antigen challenge, T-helper cells differentiate into two functionally distinct subsets, Th1 and Th2. Th1 cells produce IL-2, IFN-g and lymphotoxin-b that augment cell mediated immune response while Th2 cells secrete IL-4, IL-5, and IL-10 that enhance humoral immunity. The function of T-helper cells is regulated by cytokines. A novel cytokine receptor was recently identified and cloned. It is a new member in the type I cytokine receptor family and designated TCCR for T-cell cytokine receptor and WSX-1. TCCR deficient mice had impaired Th1 responses to protein antigen challenge, including decreased levels of IFN-g and Th1-dependent antibody IgG2a. TCCR is predominantly expressed in thymus, spleen, lymph notes and peripheral blood leukocytes.

Long Name

Interleukin-27 Receptor Subunit alpha

Alternate Names

IL-27 R alpha, IL-27Ra, IL27R alpha, IL27RA, TCCR, WSX-1

Gene Symbol

IL27RA

Additional IL-27 R alpha/WSX-1/TCCR Products

Product Documents for IL-27R alpha/WSX-1/TCCR Antibody (34N4G11) [Alexa Fluor® 350]

Certificate of Analysis

To download a Certificate of Analysis, please enter a lot number in the search box below.

Product Specific Notices for IL-27R alpha/WSX-1/TCCR Antibody (34N4G11) [Alexa Fluor® 350]



Alexa Fluor (R) products are provided under an intellectual property license from Life Technologies Corporation. The purchase of this product conveys to the buyer the non-transferable right to use the purchased product and components of the product only in research conducted by the buyer (whether the buyer is an academic or for-profit entity). The sale of this product is expressly conditioned on the buyer not using the product or its components, or any materials made using the product or its components, in any activity to generate revenue, which may include, but is not limited to use of the product or its components: (i) in manufacturing; (ii) to provide a service, information, or data in return for payment; (iii) for therapeutic, diagnostic or prophylactic purposes; or (iv) for resale, regardless of whether they are resold for use in research. For information on purchasing a license to this product for purposes other than as described above, contact Life Technologies Corporation, 5791 Van Allen Way, Carlsbad, CA 92008 USA or outlicensing@lifetech.com. This conjugate is made on demand. Actual recovery may vary from the stated volume of this product. The volume will be greater than or equal to the unit size stated on the datasheet.

This product is for research use only and is not approved for use in humans or in clinical diagnosis. Primary Antibodies are guaranteed for 1 year from date of receipt.

Loading...
Loading...
Loading...
Loading...
Loading...
Loading...