Skip to main content

SR-BI Antibody [Alexa Fluor® 532]

Novus Biologicals, part of Bio-Techne | Catalog # NB400-104AF532

Novus Biologicals, part of Bio-Techne

Key Product Details

Species Reactivity

Human, Mouse, Rat, Porcine, Chinese Hamster, Golden Syrian Hamster, Hamster, Mustelid, Primate, Rabbit

Applications

Block/Neutralize, Flow Cytometry, Immunocytochemistry/ Immunofluorescence, Immunohistochemistry, Immunohistochemistry-Frozen, Immunohistochemistry-Paraffin, Immunoprecipitation, Knockdown Validated, Knockout Validated, Proximity Ligation Assay, Simple Western, Western Blot

Label

Alexa Fluor 532

Antibody Source

Polyclonal Rabbit IgG

Concentration

Please see the vial label for concentration. If unlisted please contact technical services.

Product Specifications

Immunogen

A C-terminal peptide containing residues from mouse SR-BI (within residues 450-509). [UniProt Q61009]

Reactivity Notes

Use in Mouse reported in scientific literature (PMID:33719499).

Localization

Cell Membrane

Clonality

Polyclonal

Host

Rabbit

Isotype

IgG

Applications for SR-BI Antibody [Alexa Fluor® 532]

Application
Recommended Usage

Block/Neutralize

Optimal dilutions of this antibody should be experimentally determined.

Flow Cytometry

Optimal dilutions of this antibody should be experimentally determined.

Immunocytochemistry/ Immunofluorescence

Optimal dilutions of this antibody should be experimentally determined.

Immunohistochemistry

Optimal dilutions of this antibody should be experimentally determined.

Immunohistochemistry-Frozen

Optimal dilutions of this antibody should be experimentally determined.

Immunohistochemistry-Paraffin

Optimal dilutions of this antibody should be experimentally determined.

Immunoprecipitation

Optimal dilutions of this antibody should be experimentally determined.

Knockdown Validated

Optimal dilutions of this antibody should be experimentally determined.

Knockout Validated

Optimal dilutions of this antibody should be experimentally determined.

Proximity Ligation Assay

Optimal dilutions of this antibody should be experimentally determined.

Simple Western

Optimal dilutions of this antibody should be experimentally determined.

Western Blot

Optimal dilutions of this antibody should be experimentally determined.
Application Notes
Optimal dilution of this antibody should be experimentally determined.

Formulation, Preparation, and Storage

Purification

Immunogen affinity purified

Formulation

50mM Sodium Borate

Preservative

0.05% Sodium Azide

Concentration

Please see the vial label for concentration. If unlisted please contact technical services.

Shipping

The product is shipped with polar packs. Upon receipt, store it immediately at the temperature recommended below.

Stability & Storage

Store at 4C in the dark.

Background: SR-BI

SR-BI (scavenger receptor class B member 1, SCARB1) belongs to the CD36 family and acts as a cell surface lipoprotein receptor for a variety of ligands including high density lipoprotein (HDL), phospholipids, phosphatidylserine, and lipoproteins such as lipopolysaccharide (LPS). SR-BI mediates selective uptake of HDL cholesteryl (HDL-C) ester in the liver, steroidogenic tissues, and adipose tissue and facilitates the flux of free and esterified cholesterol between the cell surface and apoB-containing lipoproteins and modified lipoproteins. SR-BI plays a role in antigen capture and cross-presentation from bacteria, parasites, and viruses such as Hepatitis C. In endothelial cells and macrophages, SR-BI is involved in anti-inflammatory and pro-survival signaling, providing protection against atherosclerosis and clearing apoptotic cells (efferocytosis) (1, 2).

At least 5 different human splice variants have been identified with theoretical molecular weights ranging from 60.9 kDa for the canonical sequence to 45 kDa for an N-terminally truncated variant (SR-BII) (3). The extracellular domain of human SR-BI (CLA-1) shares 80%, 80%, 89%, 86% and 84% aa sequence identity with mouse, rat, porcine, rabbit, and bovine SR-BI, respectively. SR-BI is highly glycosylated and removal of N-linked glycosylation reduces lipid transport.

References

1. Linton MF, Tao H, Linton EF, Yancey PG. (2017) SR-BI: A Multifunctional Receptor in Cholesterol Homeostasis and Atherosclerosis. Trends Endocrinol Metab. 28(6):461-472. PMID: 28259375

2. Hoekstra M, Sorci-Thomas M. (2017) Rediscovering scavenger receptor type BI: surprising new roles for the HDL receptor. Curr Opin Lipidol. 28(3):255-260. PMID: 28301373

3. Shen WJ, Asthana S, Kraemer FB, Azhar S. (2018) Scavenger receptor B type 1: expression, molecular regulation, and cholesterol transport function.

Long Name

Scavenger Receptor Class B, Member I

Alternate Names

CD36L1, CLA1, HDLQTL6, SCARB1, SR-B1, SRBI

Gene Symbol

SCARB1

Additional SR-BI Products

Product Documents for SR-BI Antibody [Alexa Fluor® 532]

Certificate of Analysis

To download a Certificate of Analysis, please enter a lot number in the search box below.

Product Specific Notices for SR-BI Antibody [Alexa Fluor® 532]

Alexa Fluor (R) products are provided under an intellectual property license from Life Technologies Corporation. The purchase of this product conveys to the buyer the non-transferable right to use the purchased product and components of the product only in research conducted by the buyer (whether the buyer is an academic or for-profit entity). The sale of this product is expressly conditioned on the buyer not using the product or its components, or any materials made using the product or its components, in any activity to generate revenue, which may include, but is not limited to use of the product or its components: (i) in manufacturing; (ii) to provide a service, information, or data in return for payment; (iii) for therapeutic, diagnostic or prophylactic purposes; or (iv) for resale, regardless of whether they are resold for use in research. For information on purchasing a license to this product for purposes other than as described above, contact Life Technologies Corporation, 5791 Van Allen Way, Carlsbad, CA 92008 USA or outlicensing@lifetech.com. This conjugate is made on demand. Actual recovery may vary from the stated volume of this product. The volume will be greater than or equal to the unit size stated on the datasheet.

This product is for research use only and is not approved for use in humans or in clinical diagnosis. Primary Antibodies are guaranteed for 1 year from date of receipt.