Human CD31/PECAM-1 Quantikine ELISA Kit
R&D Systems, part of Bio-Techne | Catalog # DCD310
Key Product Details
Assay Length
Sample Type & Volume Required Per Well
Sensitivity
Assay Range
Product Summary for Human CD31/PECAM-1 Quantikine ELISA Kit
Product Specifications
Assay Type
Format
Measurement
Detection Method
Conjugate
Reactivity
Specificity
Cross-reactivity
Interference
Precision
Intra-Assay Precision (Precision within an assay) Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.
Inter-Assay Precision (Precision between assays) Three samples of known concentration were tested in twenty separate assays to assess inter-assay precision. Assays were performed by at least three technicians using two lots of components.
Cell Culture Supernates, Saliva, Urine
Intra-Assay Precision | Inter-Assay Precision | |||||
---|---|---|---|---|---|---|
Sample | 1 | 2 | 3 | 1 | 2 | 3 |
n | 20 | 20 | 20 | 20 | 20 | 20 |
Mean (ng/mL) | 1.62 | 4.70 | 9.96 | 1.71 | 5.00 | 10.6 |
Standard Deviation | 0.065 | 0.117 | 0.372 | 0.104 | 0.252 | 0.411 |
CV% | 4.0 | 2.5 | 3.7 | 6.1 | 5.0 | 3.9 |
EDTA Plasma, Heparin Plasma, Serum
Intra-Assay Precision | Inter-Assay Precision | |||||
---|---|---|---|---|---|---|
Sample | 1 | 2 | 3 | 1 | 2 | 3 |
n | 20 | 20 | 20 | 20 | 20 | 20 |
Mean (ng/mL) | 2.01 | 5.86 | 12.3 | 1.90 | 5.71 | 12.0 |
Standard Deviation | 0.070 | 0.182 | 0.403 | 0.163 | 0.363 | 0.677 |
CV% | 3.5 | 3.1 | 3.3 | 8.6 | 6.4 | 5.6 |
Recovery for Human CD31/PECAM-1 Quantikine ELISA Kit
The recovery of human CD31 spiked to levels throughout the range of the assay in various matrices was evaluated.
Sample Type | Average % Recovery | Range % |
---|---|---|
Cell Culture Media (n=4) | 103 | 96-112 |
EDTA Plasma (n=4) | 100 | 97-106 |
Heparin Plasma (n=4) | 101 | 94-108 |
Serum (n=4) | 104 | 100-107 |
Linearity
To assess the linearity of the assay, samples containing and/or spiked with high concentrations of human CD31 were diluted with Calibrator Diluent to produce samples with values within the dynamic range of the assay.
Scientific Data Images for Human CD31/PECAM-1 Quantikine ELISA Kit
Human CD31/PECAM-1 ELISA Cell Culture Supernate/Saliva/Urine Standard Curve
Human CD31/PECAM-1 ELISA Serum/Plasma Standard Curve
Preparation and Storage
Shipping
Stability & Storage
Background: CD31/PECAM-1
Long Name
Alternate Names
Gene Symbol
Additional CD31/PECAM-1 Products
Product Documents for Human CD31/PECAM-1 Quantikine ELISA Kit
Product Specific Notices for Human CD31/PECAM-1 Quantikine ELISA Kit
For research use only
⚠ WARNING: This product can expose you to chemicals including N,N-Dimethylforamide, which is known to the State of California to cause cancer. For more information, go to www.P65Warnings.ca.gov.