Human IL-1 alpha/IL-1F1 Quantikine ELISA Kit Best Seller
R&D Systems, part of Bio-Techne | Catalog # DLA50
Key Product Details
Assay Length
Sample Type & Volume Required Per Well
Sensitivity
Assay Range
Product Summary for Human IL-1 alpha/IL-1F1 Quantikine ELISA Kit
Product Specifications
Assay Type
Format
Measurement
Detection Method
Conjugate
Reactivity
Specificity
Cross-reactivity
Interference
Sample Values
Condition | Day 1 (pg/mL) | Day 5 (pg/mL) |
Unstimulated | 85 | 23 |
Stimulated | 1330 | 395 |
Precision
Intra-Assay Precision (Precision within an assay) Three samples of known concentration were tested on one plate to assess intra-assay precision.
Inter-Assay Precision (Precision between assays) Three samples of known concentration were tested in separate assays to assess inter-assay precision.
Cell Culture Supernates
Intra-Assay Precision | Inter-Assay Precision | |||||
---|---|---|---|---|---|---|
Sample | 1 | 2 | 3 | 1 | 2 | 3 |
n | 20 | 20 | 20 | 20 | 20 | 20 |
Mean (pg/mL) | 26.9 | 122 | 191 | 20.5 | 60.0 | 121 |
Standard Deviation | 0.4 | 4.6 | 6.6 | 1.7 | 3.1 | 5.2 |
CV% | 1.5 | 3.8 | 3.5 | 8.3 | 5.2 | 4.3 |
Citrate Plasma, EDTA Plasma, Heparin Plasma, Serum
Intra-Assay Precision | Inter-Assay Precision | |||||
---|---|---|---|---|---|---|
Sample | 1 | 2 | 3 | 1 | 2 | 3 |
n | 20 | 20 | 20 | 20 | 20 | 20 |
Mean (pg/mL) | 28.6 | 125 | 185 | 27.9 | 123 | 187 |
Standard Deviation | 0.4 | 1.4 | 4.0 | 1.2 | 4.7 | 6.3 |
CV% | 1.4 | 1.1 | 2.2 | 4.3 | 3.8 | 3.4 |
Recovery for Human IL-1 alpha/IL-1F1 Quantikine ELISA Kit
The recovery of IL-1 alpha spiked to levels throughout the range of the assay in various matrices was evaluated.
Sample Type | Average % Recovery | Range % |
---|---|---|
Cell Culture Media (n=4) | 96 | 91-104 |
Citrate Plasma (n=6) | 97 | 71-119 |
EDTA Plasma (n=6) | 104 | 84-121 |
Heparin Plasma (n=6) | 104 | 72-126 |
Serum (n=6) | 107 | 74-127 |
Linearity
To assess the linearity of the assay, the following biological samples spiked with high concentrations of IL-1 alpha were diluted with the appropriate Calibrator Diluent and then assayed.
Scientific Data Images for Human IL-1 alpha/IL-1F1 Quantikine ELISA Kit
Human IL-1 alpha/IL-1F1 ELISA Calibrator Diluent RD5-5 Standard Curve
Human IL-1 alpha/IL-1F1 ELISA Calibrator Diluent RD6C Standard Curve
Preparation and Storage
Shipping
Stability & Storage
Background: IL-1 alpha/IL-1F1
Long Name
Alternate Names
Entrez Gene IDs
Gene Symbol
Additional IL-1 alpha/IL-1F1 Products
Product Documents for Human IL-1 alpha/IL-1F1 Quantikine ELISA Kit
Product Specific Notices for Human IL-1 alpha/IL-1F1 Quantikine ELISA Kit
For research use only
⚠ WARNING: This product can expose you to chemicals including N,N-Dimethylforamide, which is known to the State of California to cause cancer. For more information, go to www.P65Warnings.ca.gov.