Human IL-2 Quantikine QuicKit ELISA Best Seller
R&D Systems, part of Bio-Techne | Catalog # QK202
Key Product Details
Assay Length
Sample Type & Volume Required Per Well
Sensitivity
Assay Range
Product Summary for Human IL-2 Quantikine QuicKit ELISA
Product Specifications
Measurement
Detection Method
Conjugate
Reactivity
Specificity
Cross-reactivity
Interference
Sample Values
Precision
Intra-Assay Precision (Precision within an assay) Two samples of known concentration were tested twenty times on one plate to assess intra-assay precision.
Inter-Assay Precision (Precision between assays) Two samples of known concentration were tested in ten separate assays to assess inter-assay precision. Assays were performed by at least three technicians.
Cell Culture Supernates, EDTA Plasma, Heparin Plasma, Plasma, Serum
Intra-Assay Precision | Inter-Assay Precision | |||
---|---|---|---|---|
Sample | 1 | 2 | 1 | 2 |
n | 20 | 20 | 10 | 10 |
Mean (pg/mL) | 217 | 1231 | 213 | 1331 |
Standard Deviation | 5.70 | 33.1 | 17.1 | 67.7 |
CV% | 2.6 | 2.7 | 8.0 | 5.1 |
Recovery for Human IL-2 Quantikine QuicKit ELISA
The recovery of human IL-2 spiked to three levels in samples throughout the range of the assay was evaluated.
Sample Type | Average % Recovery | Range % |
---|---|---|
Cell Culture Media (n=4) | 112 | 103-119 |
EDTA Plasma (n=2) | 85 | 72-96 |
Heparin Plasma (n=2) | 85 | 74-93 |
Serum (n=2) | 91 | 73-105 |
Linearity
To assess the linearity of the assay, samples were spiked with high concentrations of human IL-2 in various matrices and diluted with 1X Kit Diluent to produce samples with values within the dynamic range of the assay.
Scientific Data Images for Human IL-2 Quantikine QuicKit ELISA
Human IL-2 ELISA Standard Curve
Human IL-2 QuicKit Spiked Recovery Competitor Comparison
IL-2 is spiked at three known concentrations throughout the range of the assay and run to measure response of the spiked sample matrix. Serum recovery is 103% compared to 113% for the top competitor. EDTA Plasma recovery is 107% compared to 111% for the top competitor. Heparin Plasma recovery is 100% compared to 102% for the top competitor. In spike and recovery experiments, natural samples are spiked with the recombinant target analyte of interest to identify interference caused by sample matrices.Preparation and Storage
Shipping
Stability & Storage
Background: IL-2
Long Name
Alternate Names
Entrez Gene IDs
Gene Symbol
Additional IL-2 Products
Product Documents for Human IL-2 Quantikine QuicKit ELISA
Product Specific Notices for Human IL-2 Quantikine QuicKit ELISA
For research use only