Skip to main content

Human MIA Quantikine ELISA Kit

R&D Systems, part of Bio-Techne | Catalog # DMIA00

R&D Systems, part of Bio-Techne
Catalog #
Availability
Size / Price
Qty
Loading...
DMIA00

Control Products Available

Key Product Details

Assay Length

4.5 hours

Sample Type & Volume Required Per Well

Cell Culture Supernates (50 µL), Serum (25 µL), EDTA Plasma (25 µL), Heparin Plasma (25 µL), Saliva (50 µL)

Sensitivity

8.46 pg/mL

Assay Range

15.6-1000 pg/mL (Cell Culture Supernates, Serum, EDTA Plasma, Heparin Plasma, Saliva)

Product Summary for Human MIA Quantikine ELISA Kit

The Quantikine Human MIA Immunoassay is a 4.5 hour solid-phase ELISA designed to measure MIA in cell culture supernates, serum, plasma, and saliva. It contains E. coli-expressed recombinant Human MIA and antibodies raised against the recombinant factor. This immunoassay has been shown to accurately quantitate recombinant human MIA. Results obtained using natural human MIA showed linear curves that were parallel to the standard curves obtained using the Quantikine kit standards. These results indicate that this kit can be used to determine relative mass values for natural human MIA.

Product Specifications

Assay Type

Solid Phase Sandwich ELISA

Format

96-well strip plate

Measurement

Quantitative ELISA

Detection Method

Colorimetric - 450nm (TMB)

Conjugate

HRP

Reactivity

Human

Specificity

Natural and recombinant human MIA

Cross-reactivity

< 0.5% cross-reactivity observed with available related molecules. < 50% cross-species reactivity observed with species tested.

Interference

No significant interference observed with available related molecules.

Precision

Intra-Assay Precision (Precision within an assay) Three samples of known concentration were tested on one plate to assess intra-assay precision.

Inter-Assay Precision (Precision between assays) Three samples of a known concentration were tested in twenty separate assays to assess inter-assay precision. Assays were performed by at least three technicians using two lots of kit components.

Cell Culture Supernates, EDTA Plasma, Heparin Plasma, Saliva, Serum

Intra-Assay Precision Inter-Assay Precision
Sample 1 2 3 1 2 3
n 20 20 20 20 20 20
Mean (pg/mL) 158 315 622 150 308 627
Standard Deviation 5.50 10.9 17.8 7.02 15.7 37.8
CV% 3.5 3.5 2.9 4.7 5.1 6.0

Recovery for Human MIA Quantikine ELISA Kit

The recovery of MIA spiked to levels throughout the range of the assay in various matrices was evaluated.

Sample Type Average % Recovery Range %
Cell Culture Media (n=4) 103 101-107
EDTA Plasma (n=4) 98 85-115
Heparin Plasma (n=4) 99 85-113
Saliva (n=4) 102 86-110
Serum (n=4) 101 91-118

Linearity

To assess the linearity of the assay, samples containing and/or spiked with high concentrations of MIA were serially diluted with Calibrator Diluent to produce samples with values within the dynamic range of the assay. Samples were diluted prior to assay.

Human MIA ELISA Linearity

Scientific Data Images for Human MIA Quantikine ELISA Kit

Human MIA ELISA Standard Curve

Human MIA ELISA Standard Curve

Preparation and Storage

Shipping

The product is shipped at ambient temperature. Upon receipt, store it immediately at the temperature recommended below.

Stability & Storage

Store the unopened product at 2 - 8 °C. Do not use past expiration date.

Background: MIA

MIA, also known as cartilage-derived retinoic acid-sensitive protein (CD-RAP), is a secreted protein expressed in cartilaginous tissue during development and in the adult. MIA was identified based on the fact that it is highly expressed in malignant melanomas, but not in normal melanocytes. MIA has been shown to interact with fibronectin, and promotes invasion and metastasis of melanoma cells, perhaps by blocking integrin-fibronectin interactions.

Long Name

Melanoma Inhibitory Activity

Alternate Names

CD-RAP

Entrez Gene IDs

8190 (Human); 12587 (Mouse)

Gene Symbol

MIA

Additional MIA Products

Product Documents for Human MIA Quantikine ELISA Kit

Certificate of Analysis

To download a Certificate of Analysis, please enter a lot number in the search box below.

Note: Certificate of Analysis not available for kit components.

Product Specific Notices for Human MIA Quantikine ELISA Kit

For research use only

Loading...
Loading...
Loading...

⚠ WARNING: This product can expose you to chemicals including N,N-Dimethylforamide, which is known to the State of California to cause cancer. For more information, go to www.P65Warnings.ca.gov.