Exosome Standards (PC3 cell line)
Novus Biologicals, part of Bio-Techne | Catalog # NBP2-49856
Key Product Details
Applications
ELISA, Flow Cytometry, Microscopy, N/A
Product Summary for Exosome Standards (PC3 cell line)
Highly pure, lyophilized exosome standards with superior stability, optimal for multiple applications including: Assay calibration, Spike-in control for exosome quantification, Protein marker analysis for different techniques such as Western Blot and Flow Cytometry, Extraction and analysis of exosomal RNA and DNA.
Quantity per vial of 30 ug size (number of particles in 30 ug: > 1x10^8). Quantity per vial of 100 ug size (number of particles in 100 ug: > 1x10^10).
Quantity per vial of 30 ug size (number of particles in 30 ug: > 1x10^8). Quantity per vial of 100 ug size (number of particles in 100 ug: > 1x10^10).
Scientific Data Images for Exosome Standards (PC3 cell line)
Flow Cytometry: Exosome Standards (PC3 cell line) [NBP2-49856]
Flow Cytometry: Exosome Standards (PC3 cell line) [NBP2-49856] - Phenotyping assays by FACS. Reconstituted Exosomes can be used for profiling biomarkers by FACS analysis. Recommended quantity: 5 ug of reconstituted Exosomes Standards for each testFormulation, Preparation, and Storage
Preparation Method
Isolation involves Tangential flow filtration combined with Size Exclusion Chromatogrpahy. Exosomes (small EVs) are quantified and validated for protein content and particle number by Nanoparticle Tracking Analysis as well as for common tetraspanins maker validation. Lyophilization does not alter stability of exosome proteins and nucleic acids.
Formulation
Lyophilized from cell culture media
Concentration
Please see the protocols for proper use of this product. If no protocol is available, contact technical services for assistance.
Reconstitution Instructions
Add deionized water, 100 ul for Standard 100 ug and 30 ul for Standard 30 ug, to get a final concentration of 1 mg/mL. Resuspend exosomes pipetting the solution up and down 10-15 times, avoiding bubbles. Vortex the reconstituted standard for 60 seconds.
Shipping
The product is shipped with polar packs. Upon receipt, store it immediately at the temperature recommended below.
Storage
Store at 4C. After reconstitution store at -70C.
Background: Exosome Standards (PC3 cell line)
Additional Exosome Standards (PC3 cell line) Products
Product Documents for Exosome Standards (PC3 cell line)
Product Specific Notices for Exosome Standards (PC3 cell line)
This product is for research use only and is not approved for use in humans or in clinical diagnosis. Support products are guaranteed for 6 months from date of receipt.
Loading...
Loading...
Loading...
Loading...