Skip to main content

beta-Actin Antibody (8H10D10) [Alexa Fluor® 594]

Novus Biologicals, part of Bio-Techne | Catalog # NBP1-47423AF594

Novus Biologicals, part of Bio-Techne
Catalog #
Availability
Size / Price
Qty
Loading...
NBP1-47423AF594

Key Product Details

Species Reactivity

Human, Mouse, Rat, Chinese Hamster, Primate

Applications

ELISA, Flow (Intracellular), Flow Cytometry, Immunoblotting, Immunocytochemistry/ Immunofluorescence, Simple Western, Western Blot

Label

Alexa Fluor 594 (Excitation = 590 nm, Emission = 617 nm)

Antibody Source

Monoclonal Mouse IgG2B Clone # 8H10D10

Concentration

Please see the vial label for concentration. If unlisted please contact technical services.

Product Specifications

Immunogen

This beta-Actin Antibody (8H10D10) was made to a synthetic peptide corresponding to amino-terminal residues of human Beta Actin, conjugated to KLH. [UniProt# P60709]

Localization

Cytoplasm, cytoskeleton.

Clonality

Monoclonal

Host

Mouse

Isotype

IgG2B

Theoretical MW

42 kDa.
Disclaimer note: The observed molecular weight of the protein may vary from the listed predicted molecular weight due to post translational modifications, post translation cleavages, relative charges, and other experimental factors.

Scientific Data Images for beta-Actin Antibody (8H10D10) [Alexa Fluor® 594]

Product Image: beta-Actin Antibody (8H10D10) [Alexa Fluor® 594] [NBP1-47423AF594] - Vial of Alexa Fluor 594 conjugated antibody. Alexa Fluor 594 is optimally excited at 590 nm by the Yellow-Green laser (561 nm) and has an emission maximum of 617 nm.

Applications for beta-Actin Antibody (8H10D10) [Alexa Fluor® 594]

Application
Recommended Usage

ELISA

Optimal dilutions of this antibody should be experimentally determined.

Flow (Intracellular)

Optimal dilutions of this antibody should be experimentally determined.

Flow Cytometry

Optimal dilutions of this antibody should be experimentally determined.

Immunoblotting

Optimal dilutions of this antibody should be experimentally determined.

Immunocytochemistry/ Immunofluorescence

Optimal dilutions of this antibody should be experimentally determined.

Simple Western

Optimal dilutions of this antibody should be experimentally determined.

Western Blot

Optimal dilutions of this antibody should be experimentally determined.
Application Notes
Optimal dilution of this antibody should be experimentally determined.

Formulation, Preparation, and Storage

Purification

Ammonium sulfate precipitation

Formulation

50mM Sodium Borate

Preservative

0.05% Sodium Azide

Concentration

Please see the vial label for concentration. If unlisted please contact technical services.

Shipping

The product is shipped with polar packs. Upon receipt, store it immediately at the temperature recommended below.

Stability & Storage

Store at 4C in the dark.

Background: beta-Actin

Actin is a highly conserved protein involved in cell motility, structure, and integrity. Six functional actin isoforms exist and were named based on their electrophoretic mobility and distribution including alpha-cardiac muscle actin (aCAA), alpha-skeletal muscle actin (aSKA), alpha-smooth muscle actin (aSMA), beta-cytoplasmic actin (bCYA), gamma-cytoplasmic actin (gCYA) and gamma-smooth muscle actin (gSMA) (1). The cytoplasmic isoforms, beta-actin and gamma-actin, are nearly identical, differing by only 4 amino acids at the N-terminus with a theoretical molecular weight of 42 kDa (2). Beta-actin is ubiquitously expressed in eukaryotic cells and considered a housekeeping gene which is frequently used as a loading control for assays involving protein detection, such as Western blotting (3,4).

References

1. Vandekerckhove J, Weber K. 1978. At least six different actins are expressed in a higher mammal: an analysis based on the amino acid sequence of the amino-terminal tryptic peptide. J Mol Biol. 126(4):783-802. PMID: 745245

2. Gimona M, Vandekerckhove J, Goethals M, Herzog M, Lando Z, Small JV. (1994) Beta-actin specific monoclonal antibody. Cell Motil Cytoskeleton. 27(2):108-16. PMID: 8162619

3. Holden VI, Lenio S, Kuick R, Ramakrishnan SK, Shah YM, Bachman MA. (2014) Bacterial siderophores that evade or overwhelm Lipocalin 2 induce HIF-1a and pro-inflammatory cytokine secretion in cultured respiratory epithelial cells Infect Immun. 82(9):3826-36 PMID: 24980968

4. Tsai WL, Yeh PH, Tsai CY, Ting CT, Chiu YH, Tao MH, Li WC, Hung SC. (2016) Efficient Programming of Human Mesenchymal Stem Cell Derived Hepatocytes by Epigenetic Regulations. J. Gastroenterol. Hepatol. 32(1):261-269. PMID: 27218433

Alternate Names

ACTB, betaActin

Gene Symbol

ACTB

Additional beta-Actin Products

Product Documents for beta-Actin Antibody (8H10D10) [Alexa Fluor® 594]

Certificate of Analysis

To download a Certificate of Analysis, please enter a lot number in the search box below.

Product Specific Notices for beta-Actin Antibody (8H10D10) [Alexa Fluor® 594]

Alexa Fluor (R) products are provided under an intellectual property license from Life Technologies Corporation. The purchase of this product conveys to the buyer the non-transferable right to use the purchased product and components of the product only in research conducted by the buyer (whether the buyer is an academic or for-profit entity). The sale of this product is expressly conditioned on the buyer not using the product or its components, or any materials made using the product or its components, in any activity to generate revenue, which may include, but is not limited to use of the product or its components: (i) in manufacturing; (ii) to provide a service, information, or data in return for payment; (iii) for therapeutic, diagnostic or prophylactic purposes; or (iv) for resale, regardless of whether they are resold for use in research. For information on purchasing a license to this product for purposes other than as described above, contact Life Technologies Corporation, 5791 Van Allen Way, Carlsbad, CA 92008 USA or outlicensing@lifetech.com. This conjugate is made on demand. Actual recovery may vary from the stated volume of this product. The volume will be greater than or equal to the unit size stated on the datasheet.

This product is for research use only and is not approved for use in humans or in clinical diagnosis. Primary Antibodies are guaranteed for 1 year from date of receipt.

Loading...
Loading...
Loading...
Loading...
Loading...
Loading...