Skip to main content

Total Nitric Oxide and Nitrate/Nitrite Parameter Assay Kit

R&D Systems, part of Bio-Techne | Catalog # KGE001

R&D Systems, part of Bio-Techne
Catalog #
Availability
Size / Price
Qty
Loading...
KGE001
PKGE001
SKGE001

Control Products Available

Key Product Details

Assay Length

< 1 hour

Sample Type & Volume Required Per Well

Cell Culture Supernates (10 µL), Serum (25 µL), EDTA Plasma (25 µL), Heparin Plasma (25 µL), Citrate Plasma (25 µL), Urine (10 µL)

Sensitivity

0.78 µmol/L

Assay Range

3.12-200 µmol/L (Cell Culture Supernates, Serum, EDTA Plasma, Heparin Plasma, Citrate Plasma, Urine)

Product Summary for Total Nitric Oxide and Nitrate/Nitrite Parameter Assay Kit

The Parameter Total Nitric Oxide kit has two assay options. Endogenous nitrite is measured in the first option. In the second option, nitrate is converted to nitrite using nitrate reductase and total nitrite is measured. To obtain the nitrate concentration, endogenous nitrite is subtracted from the total nitrite value.

Product Specifications

Format

96-well strip plate

Measurement

Quantitative ELISA

Detection Method

Colorimetric - 450nm (TMB)

Reactivity

Multi-Species

Specificity

Measures Total Nitric Oxide, Nitrite and Nitrate levels in various samples

Cross-reactivity

< 0.5% cross-reactivity observed with available related molecules. < 50% cross-species reactivity observed with species tested.

Interference

Interference observed with other substances.

Precision

Intra-Assay Precision (Precision within an assay) Three samples of known concentration were tested on one plate to assess intra-assay precision.

Inter-Assay Precision (Precision between assays) Three samples of known concentration were tested in separate assays to assess inter-assay precision.

Cell Culture Supernates, Citrate Plasma, EDTA Plasma, Heparin Plasma, Serum, Urine

Intra-Assay Precision Inter-Assay Precision
Sample 1 2 3 1 2 3
n 20 20 20 40 40 40
Mean (µmol/L) 30.0 77.2 138.0 31.5 79.9 138.7
Standard Deviation 0.76 1.10 2.20 1.46 2.91 4.78
CV% 2.5 1.4 1.6 4.6 3.6 3.4

Recovery for Total Nitric Oxide and Nitrate/Nitrite Parameter Assay Kit

The recovery of the nitrate standard spiked to levels throughout the range of the assay in various matrices was evaluated.

Sample Type Average % Recovery Range %
Cell Culture Supernates (Nitrite Assay) (n=10) 107 91-115
Plasma (Nitrate Assay) (n=25) 98 87-110
Plasma (Nitrite Assay) (n=20) 104 92-117
Serum (Nitrate Assay) (n=10) 95 89-101
Serum (Nitrite Assay) (n=10) 109 98-118
Urine (Nitrite Assay) (n=10) 101 87-112

Linearity

To assess the linearity of the assay, samples containing and/or spiked with high concentrations of the nitrate standard were serially diluted with the Reaction Diluent to produce samples with values within the dynamic range of the assay.

Multi-species Total Nitric Oxide and Nitrate/Nitrite ELISA Linearity

Scientific Data Images for Total Nitric Oxide and Nitrate/Nitrite Parameter Assay Kit

Multi-species Total Nitric Oxide and Nitrate/Nitrite ELISA Standard Curve

Multi-species Total Nitric Oxide and Nitrate/Nitrite ELISA Standard Curve

Preparation and Storage

Shipping

The product is shipped at ambient temperature. Upon receipt, store it immediately at the temperature recommended below.

Stability & Storage

Store the unopened product at 2 - 8 °C. Do not use past expiration date.

Background: Nitric Oxide

Additional Nitric Oxide Products

Product Documents for Total Nitric Oxide and Nitrate/Nitrite Parameter Assay Kit

Certificate of Analysis

To download a Certificate of Analysis, please enter a lot number in the search box below.

Note: Certificate of Analysis not available for kit components.

Product Specific Notices for Total Nitric Oxide and Nitrate/Nitrite Parameter Assay Kit

For research use only