TIRAP (TLR2 and TLR4) Inhibitor Peptide Set
Novus Biologicals, part of Bio-Techne | Catalog # NBP2-31274
Key Product Details
Species
Human, Mouse
Applications
Flow Cytometry, Functional Assay
Product Specifications
Specificity
TLR2 and TLR4 Inhibitor Peptide: COBRA
TLR2 and TLR4 Inhibitor interferes with interaction between TIRAP/Mal and TIR domain of TLR2 or TLR4.
TLR2 and TLR4 Inhibitor interferes with interaction between TIRAP/Mal and TIR domain of TLR2 or TLR4.
Application Notes
The inhibitor is used in assays to inhibit TLR2 and TLR4 signaling. We recommend an initial titration of the inhibitor from 0-50 uM for in vitro assays along with control of which concentrations should be mirror inhibitor concentrations. Inhibitor and control should be preincubated with cells prior to ligand activation to allow sufficient time for the peptides to enter from the media into the cell. We typically preincubate with inhibitor and control for 1 h prior to TLR2 or TLR4 activation (Figures 1 and 2); however, optimal preincubation times may vary between model systems. FLOW and Functional application reported by Alvarez et al - Conference on Retroviruses and Opportunistic Infections - CROI 2014 (Abstract: The NCOR2-Nurr1-CoREST Transrepression Axis Impairs HIV Reactivation in Latently Infected Microglial Cells)
Inhibitor Content
Antennapedia Control Peptide: 1 mg (lyophilized); sequence: DRQIKIWFQNRRMKWKK; Molecular weight: 2361 Da
Formulation, Preparation, and Storage
Preparation Method
Preparation of 2.5 mM peptide stock solutions
TLR2 / TLR4 Inhibitor Peptide: A final volume of 100 ul will make a 2.5 mM stock solution. Add 100 ul sterile water to the tube of peptide. Carefully pipet to ensure all of the peptide is dissolved and briefly spin the tube before opening.
The stock solutions may be diluted further to make working solutions. Dilute according to the needs for your assay. For example, dilute 2.5 mM stock solutions 1:10 in sterile 1X PBS or cell culture media to make 250 uM working solutions. Working solution should be made fresh daily and not be stored.
TLR2 / TLR4 Inhibitor Peptide: A final volume of 100 ul will make a 2.5 mM stock solution. Add 100 ul sterile water to the tube of peptide. Carefully pipet to ensure all of the peptide is dissolved and briefly spin the tube before opening.
The stock solutions may be diluted further to make working solutions. Dilute according to the needs for your assay. For example, dilute 2.5 mM stock solutions 1:10 in sterile 1X PBS or cell culture media to make 250 uM working solutions. Working solution should be made fresh daily and not be stored.
Formulation
Lyophilized white powder
Concentration
Lyoph
Reconstitution Instructions
Please contact technical support for detailed reconstitution instructions.
Shipping
The product is shipped with polar packs. Upon receipt, store it immediately at the temperature recommended below.
Storage
Store at -20C. Avoid freeze-thaw cycles.
Background: TIRAP (TLR2 and TLR4)
Alternate Names
adapter protein wyatt, Adaptor protein Wyatt, FLJ42305, MAL, MyD88 adapter-like protein, TIR domain-containing adapter protein, toll/interleukin-1 receptor domain-containing adapter protein, toll-interleukin 1 receptor (TIR) domain containing adaptor protein, Toll-interleukin 1 receptor (TIR) domain-containing adaptor protein, Toll-like receptor adaptor protein, wyatt
Gene Symbol
TIRAP
Additional TIRAP (TLR2 and TLR4) Products
Product Documents for TIRAP (TLR2 and TLR4) Inhibitor Peptide Set
Product Specific Notices for TIRAP (TLR2 and TLR4) Inhibitor Peptide Set
This product is for research use only and is not approved for use in humans or in clinical diagnosis. Inhibitors are guaranteed for 1 year from date of receipt.