Human CXCL10/IP-10 ELISA Kit - Quantikine Best Seller
R&D Systems, part of Bio-Techne | Catalog # DIP100
Key Product Details
Assay Length
Sample Type & Volume Required Per Well
Sensitivity
Assay Range
Product Summary for Human CXCL10/IP-10 Quantikine ELISA Kit
Product Specifications
Assay Type
Format
Measurement
Detection Method
Conjugate
Reactivity
Specificity
Cross-reactivity
Interference
Sample Values
Sample Type | Mean (pg/mL) | Range (pg/mL) |
Serum (n=60) | 89 | 38-361 |
EDTA plasma (n=35) | 96 | 47-382 |
Heparin plasma (n=35) | 110 | 52-450 |
Saliva (n=5) | 729 | 292-1340 |
Sample Type | Mean of Detectable (pg/mL) | % Detectable | Range (pg/mL) |
Urine (n=18) | 17.2 | 67 | ND-49.7 |
Condition | Day 1 (pg/mL) | Day 5 (pg/mL) |
Unstimulated | 29,774 | 21,900 |
Stimulated | 18,456 | 11,091 |
THP-1 human acute monocyte leukemia cells were cultured in RPMI supplemented with 10% fetal bovine serum, 50 μM beta-mercaptoethanol, 2 mM L-glutamine, 100 U/mL penicillin, and 100 μg/mL streptomycin sulfate. Cells were stimulated with 1.0 μg/mL recombinant human IFN-gamma for 8 hours and then 1.0 μg/mL LPS was added. Cells were incubated for an additional 18 hours. An aliquot of the cell culture supernate was removed, diluted 600-fold and assayed, and measured 164,640 pg/mL.
Precision
Intra-Assay Precision (Precision within an assay) Three samples of known concentration were tested on one plate to assess intra-assay precision.
Inter-Assay Precision (Precision between assays) Three samples of known concentration were tested in separate assays to assess inter-assay precision.
Cell Culture Supernates, Saliva, Urine
Intra-Assay Precision | Inter-Assay Precision | |||||
---|---|---|---|---|---|---|
Sample | 1 | 2 | 3 | 1 | 2 | 3 |
n | 20 | 20 | 20 | 40 | 40 | 40 |
Mean (pg/mL) | 70.3 | 174 | 342 | 80.7 | 194 | 362 |
Standard Deviation | 2.07 | 5.15 | 10.74 | 7.91 | 13.48 | 24.27 |
CV% | 2.9 | 3.0 | 3.1 | 9.8 | 6.9 | 6.7 |
EDTA Plasma, Heparin Plasma, Serum
Intra-Assay Precision | Inter-Assay Precision | |||||
---|---|---|---|---|---|---|
Sample | 1 | 2 | 3 | 1 | 2 | 3 |
n | 20 | 20 | 20 | 40 | 40 | 40 |
Mean (pg/mL) | 67.4 | 168 | 334 | 70.7 | 182 | 366 |
Standard Deviation | 3.12 | 4.99 | 11.15 | 6.23 | 11.12 | 18.93 |
CV% | 4.6 | 3.0 | 3.3 | 8.8 | 6.1 | 5.2 |
Recovery for Human CXCL10/IP-10 Quantikine ELISA Kit
The recovery of IP-10 spiked to levels throughout the range of the assay in various matrices was evaluated.
Sample Type | Average % Recovery | Range % |
---|---|---|
Cell Culture Media (n=4) | 95 | 88-101 |
EDTA Plasma (n=5) | 99 | 90-109 |
Heparin Plasma (n=5) | 99 | 87-113 |
Serum (n=5) | 99 | 88-112 |
Linearity
To assess the linearity of the assay, samples containing and/or spiked with high concentrations of IP-10 were serially diluted with the appropriate Calibrator Diluent to produce samples with values within the dynamic range of the assay.
Scientific Data Images for Human CXCL10/IP-10 Quantikine ELISA Kit
Human CXCL10/IP-10/CRG-2 ELISA Calibrator Diluent RD5K Standard Curve
Human CXCL10/IP-10/CRG-2 ELISA Calibrator Diluent RD6Q Standard Curve
Preparation and Storage
Shipping
Stability & Storage
Background: CXCL10/IP-10/CRG-2
Additional CXCL10/IP-10/CRG-2 Products
Product Documents for Human CXCL10/IP-10 Quantikine ELISA Kit
Product Specific Notices for Human CXCL10/IP-10 Quantikine ELISA Kit
For research use only
⚠ WARNING: This product can expose you to chemicals including N,N-Dimethylforamide, which is known to the State of California to cause cancer. For more information, go to www.P65Warnings.ca.gov.