Human Fibronectin Quantikine ELISA Kit Best Seller
R&D Systems, part of Bio-Techne | Catalog # DFBN10
Key Product Details
Assay Length
Sample Type & Volume Required Per Well
Sensitivity
Assay Range
Product Summary for Human Fibronectin Quantikine ELISA Kit
Product Specifications
Assay Type
Format
Measurement
Detection Method
Conjugate
Reactivity
Specificity
Cross-reactivity
Interference
Precision
Intra-Assay Precision (Precision within an assay) Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.
Inter-Assay Precision (Precision between assays) Three samples of known concentration were tested in twenty separate assays to assess inter-assay precision. Assays were performed by at least three technicians using two lots of components.
Cell Culture Supernates, Cell Lysates, Citrate Plasma, EDTA Plasma, Heparin Plasma, Human Milk, Saliva, Serum, Urine
Intra-Assay Precision | Inter-Assay Precision | |||||
---|---|---|---|---|---|---|
Sample | 1 | 2 | 3 | 1 | 2 | 3 |
n | 20 | 20 | 20 | 20 | 20 | 20 |
Mean (ng/mL) | 24.0 | 58.1 | 123 | 23.3 | 56.5 | 115 |
Standard Deviation | 1.40 | 2.78 | 6.35 | 1.31 | 2.98 | 6.38 |
CV% | 5.8 | 4.8 | 5.2 | 5.6 | 5.3 | 5.5 |
Recovery for Human Fibronectin Quantikine ELISA Kit
The recovery of human Fibronectin spiked to levels throughout the range of the assay was evaluated.
Sample Type | Average % Recovery | Range % |
---|---|---|
Cell Culture Media (n=4) | 97 | 89-115 |
Linearity
To assess the linearity of the assay, samples containing and/or spiked with high concentrations of human Fibronectin were diluted with Calibrator Diluent to produce samples with values within the dynamic range of the assay. Samples were diluted prior to assay.
Scientific Data Images for Human Fibronectin Quantikine ELISA Kit
Human Fibronectin ELISA Standard Curve
Preparation and Storage
Shipping
Stability & Storage
Background: Fibronectin
Fibronectin is an extracellular matrix (ECM) component and is one of the primary cell adhesion molecules. The occurrence of different isoforms is due to alternative mRNA splicing of the ED-A, ED-B and III-CS regions, and subsequent post-translational modification. Although non-reactive with adhesion receptors in its soluble state, fibronectin is highly adhesive when immobilized on a surface.
Alternate Names
Gene Symbol
Additional Fibronectin Products
Product Documents for Human Fibronectin Quantikine ELISA Kit
Product Specific Notices for Human Fibronectin Quantikine ELISA Kit
For research use only