Human Leptin Quantikine QuicKit ELISA
R&D Systems, part of Bio-Techne | Catalog # QK398
Key Product Details
Assay Length
Sample Type & Volume Required Per Well
Sensitivity
Assay Range
Product Summary for Human Leptin Quantikine QuicKit ELISA
Product Specifications
Measurement
Detection Method
Conjugate
Reactivity
Specificity
Cross-reactivity
Interference
Precision
Intra-Assay Precision (Precision within an assay) Two samples of known concentration were tested twenty times on one plate to assess intra-assay precision.
Inter-Assay Precision (Precision between assays) Two samples of known concentration were tested in ten separate assays to assess inter-assay precision. Assays were performed by at least three technicians.
EDTA Plasma, Heparin Plasma, Serum
Intra-Assay Precision | Inter-Assay Precision | |||
---|---|---|---|---|
Sample | 1 | 2 | 1 | 2 |
n | 20 | 20 | 10 | 10 |
Mean (pg/mL) | 134 | 709 | 130 | 709 |
Standard Deviation | 2.84 | 15.8 | 11.9 | 19.7 |
CV% | 2.1 | 2.2 | 9.2 | 2.8 |
Recovery for Human Leptin Quantikine QuicKit ELISA
The recovery of human Leptin spiked to three levels in samples throughout the range of the assay was evaluated.
Sample Type | Average % Recovery | Range % |
---|---|---|
Cell Culture Media (n=4) | 89 | 80-106 |
Linearity
To assess the linearity of the assay, samples containing and/or spiked with high concentrations of human Leptin were diluted with calibrator diluent to produce samples with values within the dynamic range of the assay. Samples were diluted prior to assay.
Scientific Data Images for Human Leptin Quantikine QuicKit ELISA
Human Leptin ELISA Standard Curve
Human Leptin QuicKit Spiked Recovery Competitor Comparison
Leptin is spiked at three known concentrations throughout the range of the assay and run to measure response of the spiked sample matrix. Serum recovery is 74% compared to 70% for the top competitor. EDTA plasma recovery is 84% compared to 69% for the top competitor. Heparin plasma recovery is 88% compared to 77% for the top competitor. In spike and recovery experiments, natural samples are spiked with the recombinant target analyte of interest to identify interference caused by sample matrices.Human Leptin QuicKit Linearity Competitor Comparison
Samples containing and/or spiked with high concentrations of Leptin in various matrices and diluted with appropriate Calibrator Diluent to produce samples with values within the dynamic range of the assay. The linearity is between 99%-106% compared to 71%-122% for the top competitor.Preparation and Storage
Shipping
Stability & Storage
Background: Leptin/OB
Additional Leptin/OB Products
Product Documents for Human Leptin Quantikine QuicKit ELISA
Product Specific Notices for Human Leptin Quantikine QuicKit ELISA
For research use only